DSpace JSPUI


DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More

Please use this identifier to cite or link to this item: http://repositorio.insp.mx:8080/jspui/handle/20.500.12096/8091
Full metadata record
DC FieldValueLanguage
dc.coverage.spatialnacional
dc.creatorAGUILAR ESPINOSA, ANDREA VIRGINIA
dc.date.accessioned2023-05-25T14:21:04Z-
dc.date.available2023-05-25T14:21:04Z-
dc.date.issued2020
dc.identifier.urisicabi.insp.mx:2020-None
dc.identifier.urihttps://reader.elsevier.com/reader/sd/pii/S1876034119303399?token=847457B53A6759BFFC83481B87FE810B769F97D7E7F6C47C5AA52FC7B37B38DB2C2B72B278F50BDF091656012E599690&originRegion=us-east-1&originCreation=20230116162348
dc.identifier.urihttps://www.doi.org/ 10.1016/j.jiph.2019.11.002
dc.identifier.urihttp://repositorio.insp.mx:8080/jspui/handle/20.500.12096/8091-
dc.description.abstractAbstract Background: Human immunodeficiency virus (HIV) incidence should be calculated in cross-sectional studies using recent infection testing algorithms (RITA) that consider clinical variables and serological test results such as enzyme-linked immunosorbent assay (ELISA) and dried blood spot (DBS) analysis. Methods: The correlation between serum samples and DBS was evaluated using two commercial ELISA kits: SediaTM BED HIV-1 Incidence EIA (BED-Sedia) and Maxim HIV-1 Limiting Antigen Avidity (LAg-Avidity). Eight different RITAs were developed; all of them included serological assays. A combination of the variables viral load, antiretroviral therapy (ART) and CD4 count was used to build the RITAs. The sensitivity, specificity, Youden index, predictive positive value, predictive negative value, false recent rate (FRR) and false long-term rate were evaluated. Results: The correlations between serum samples and DBS were 0.990 and 0.867 for BED-Sedia and LAg-avidity, respectively. Using only serological assays, the Youden index was higher for LAg-avidity than BED-Sedia (82.1-83.0% versus 69.2-69.6%). The best RITA was ART-serology, which showed a Youden index of 91.2-93.9% and FRR of 1.8-2.2%. Conclusions: Using DBS samples to determine HIV incidence is a good tool for epidemiological surveillance. The RITA that included ART and serological tests (BED-Sedia or LAg-avidity) showed the highest sensitivity and specificity and a low FRR.
dc.formatpdf
dc.languagespa
dc.publisherESPM INSP
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.subjectAIDS Serodiagnosis, , methods AIDS Serodiagnosis, , statistics numerical data Algorithms CD4 Lymphocyte Count Dried Blood Spot Testing Enzyme-Linked Immunosorbent Assay HIV Infections , epidemiology, HIV Infections , virology Homosexuality, Male , statistics numerical data, Humans Incidence Male Mexico , epidemiology Viral Load
dc.titleEvaluation of an HIV recent infection testing algorithm with serological assays among men who have sex with men in Mexico
dc.typeinfo:eu-repo/semantics/article
dc.subject.ctiinfo:eu-repo/classification/cti/3
dc.creator.curpcurp/AUEA911115MDFGSN00;AGUILAR ESPINOSA, ANDREA VIRGINIA
dc.creator.orcidorcid/0000-0002-2302-9100;García-Cisneros, Santa
dc.creator.orcidorcid/0000-0001-6307-0370;Herrera Ortiz, Antonia
dc.creator.orcidorcid/0000-0001-5857-6625;López Gatell, Hugo
dc.creator.orcidorcid/0000-0002-5227-7541;Olamendi Portugal, Maria
dc.creator.orcidorcid/0000-0003-0032-3849;RUIZ-GONZALEZ, VERONICA
dc.creator.orcidorcid/0000-0003-2383-7930;Sánchez Alemán, Miguel Angel
Appears in Collections:Artículos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.